Goodman - 4 Ton/48,000 BTU High Efficiency Heat Pump Condenser- 15.2 SEER2 - Single Stage - R32 - GLZS5BA4810
The Goodman GLZS5BA4810 heat pump condenser is one of the most efficient on the market. This means you'll save money both upfront and on your energy bills. It's a great choice for many homes and businesses.
Please note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.
Features
- Designed to cover a smaller house in average climates
- 4 Ton, 15.2 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
Specifications
| 4 Ton 15.2 SEER2 High Efficiency Goodman Heat Pump - 7.8 HSPF2 |
| SKU |
GLZS5BA4810 |
| Weight (in lbs) |
292.000000 |
| Brand/Manufacturer |
Goodman |
| Replaces |
GSZ160481 |
| Product Features |
New Refrigerant Compliant |
| Cooling BTU |
48,000 |
| Heating BTU |
48,000 |
| Decibel Level (dBA) |
74 |
| Horsepower |
0.25 HP |
| Refrigerant |
R32 |
| SEER2 (Efficiency) |
15.2 |
| Condenser Stages |
Single Stage |
| Compressor Type |
Scroll |
| Liquid Line |
3/8" |
| Suction Line |
1 1/8" |
| Electrical |
208/230v 1 Phase 60Hz |
| Max Breaker Size |
45 Amps |
| Min. Breaker Size |
26.2 Amps |
| Tonnage |
4 Ton |
| Connection |
Sweat |
| Height |
36 1/2" |
| Width |
35 1/2" |
| Depth |
35 1/2" |
Manual
What our Experts Think
-
Balanced Heating & Cooling Power: The Goodman GLZS5BA4810 Heat Pump Condenser is a 4‑ton (48,000 BTU) heat pump condenser that delivers effective year‑round comfort, providing both cooling and heat performance in one outdoor unit.
-
Strong Seasonal Efficiency: With a 15.2 SEER2 rating, this heat pump offers solid energy efficiency that helps lower utility costs compared with lower SEER2 systems — a practical choice for many homeowners seeking efficiency without premium pricing.
-
Single‑Stage Scroll Compressor: The single‑stage scroll compressor ensures reliable performance and simplified operation with fewer components to maintain, contributing to long‑term dependability.
-
R‑32 Refrigerant Advantage: Using R32 refrigerant, this unit supports effective heat transfer and a lower environmental footprint than older refrigerants, aligning with modern HVAC standards.
-
Durable Outdoor Construction: Built with a heavy‑gauge galvanized‑steel cabinet, corrosion‑resistant finish, and robust protective guards, this condenser is designed to withstand outdoor elements and demanding conditions.
-
Quiet & Practical Operation: Features like SmartShift® technology for reliable defrost cycles and factory‑installed protections contribute to more consistent performance and reduced noise during operation.
-
Great Value Heat Pump Choice: Combining year‑round performance, energy efficiency, and proven Goodman build quality, this heat pump condenser is a smart, cost‑effective solution for comfort upgrades or whole‑home replacements.
Q&A
Q: What kind of HVAC unit is this?
A: This is a 4 ton (48,000 BTU) heat pump condenser outdoor unit designed for both cooling and heating when paired with a compatible indoor air handler or coil — an efficient all‑season comfort solution.
Q: What does SEER2 15.2 mean?
A: SEER2 15.2 reflects modern seasonal cooling efficiency under updated test standards, helping reduce energy use and electricity costs compared with lower‑rated systems.
Q: What refrigerant does this unit use?
A: The GLZS5BA4810 uses R32 refrigerant, a newer, more energy‑efficient refrigerant with a lower environmental impact than many older refrigerants.
Q: What are the heating capabilities?
A: As a heat pump, it also provides about 48,000 BTU of heating capacity, making it effective in mild to moderate climates when paired with the right indoor unit.
Q: What compressor and stages does it feature?
A: It uses a single‑stage scroll compressor for reliable cooling and heating performance with a simple, dependable design.
Q: How durable and service‑ready is the unit?
A: Features include fully enclosed contactor and ground lug, service valves with sweat connections, extended‑life capacitor, and SmartShift® defrost technology for smooth heating cycles.
Q: What are the electrical and install requirements?
A: Designed for 208/230 V single‑phase power, fully charged for up to ~15 ft of line set, and AHRI/ETL Certified for verified performance and safety.
Q: How quiet is the unit?
A: Operating noise is around 73–74 dBA, typical for residential outdoor heat pumps.
Maintenance Tips
-
Clean the Outdoor Coil: Remove leaves, dirt, and debris regularly to maintain efficient heat transfer and optimal heating/cooling performance.
-
Maintain Proper Clearance: Keep at least 2–3 ft of space around the condenser for unrestricted airflow.
-
Inspect Refrigerant Lines: Check liquid and suction lines for insulation damage or leaks to prevent efficiency loss.
-
Rinse Fins Carefully: Use a garden hose to clean condenser fins without bending or damaging them.
-
Check Electrical Connections: Ensure wiring, disconnects, and capacitors are secure and free from corrosion.
-
Monitor Performance & Noise: Normal operation should be quiet; unusual sounds or reduced heating/cooling may indicate maintenance needs.
-
Schedule Annual Professional Service: A licensed HVAC technician should inspect the compressor, fan motor, refrigerant charge, and system pressures yearly.