Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3

Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3

Regular price $4,411.80 Sale price$4,329.00 Save 2%
/

  • Free worldwide shipping

Goodman - 2 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.8 SEER2 - R32 - CHPTA2426B3 

Features
  • Ideal size to cover a medium-sized house
  • 2 ton, 13.4 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed filter drier
  • 2 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a medium house (depending on climate)
  • 60,000 BTU 96% efficient natural gas furnace
  • Requires plastic/pvc flue venting
  • Can be used in the downflow or horizontal orientation
  • Can be converted to an LP furnace with a conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS3BN2410
Weight 130.000000
Manufacturer Goodman
Replaces GSX130241 and GSXN3N2410
Product Features New Refrigerant Compliant
Cooling BTU 24,000
Decibel Level (dBA) 74
Horsepower 1/8 HP
Refrigerant R32
SEER2 13.4
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208 / 230 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 2 Ton
Connection Sweat
Height 27.5"
Width 26"
Depth 26"
Manual
What our Experts Think
  • All‑Season Comfort Package – A complete system pairing a 2 ton air conditioner with a 60,000 BTU, 96% AFUE gas furnace for reliable year‑round heating and cooling in small to mid‑size homes.

  • 96% AFUE High Heating Efficiency – High furnace efficiency means more of the fuel becomes heat, helping reduce winter heating costs compared with standard units.

  • 13.8 SEER2 Cooling Performance – Delivers efficient cooling that meets modern energy standards, helping lower summer electricity use while improving indoor comfort.

  • Horizontal Installation Ready – Designed for horizontal duct layouts (attic or crawl space), offering flexibility for common residential installations.

  • R‑32 Refrigerant Compliance – Uses modern, lower‑impact R‑32 refrigerant, aligning with current environmental and efficiency standards.

  • Factory‑Matched Coil & TXV – The included horizontal evaporator coil with built‑in TXV improves refrigerant control and overall system efficiency when properly paired.

  • Durable Construction & Warranty Support – Quality cased coil design and Goodman’s 10‑year parts warranty (with registration) help ensure long‑term reliability.

  • Balanced Performance & Value – A well‑rounded system for homeowners who want solid performance and comfort without the premium cost of ultra‑high SEER or modulating systems.


Q&A

Q: What’s included in this Goodman HVAC system?
A: This matched comfort system includes a Goodman 2 ton 13.8 SEER2 R32 air conditioner condenser, a horizontal CHPTA2426B3 evaporator coil with factory‑installed TXV, and a 96% AFUE 60,000 BTU gas furnace engineered to work together for efficient heating and cooling.

Q: What size home is this system suited for?
A: With 2 ton (≈24,000 BTU) cooling and 60,000 BTU heating, it’s ideal for small to medium homes (~1,000–1,800 sq ft), depending on insulation, local climate, and duct design.

Q: What does 13.8 SEER2 mean?
A: 13.8 SEER2 is the seasonal energy efficiency rating for cooling. It means efficient cooling performance that can help lower electricity use compared with older or lower‑rated systems.

Q: What does 96% AFUE mean?
A: 96% AFUE indicates 96% of the fuel’s energy is converted to usable heat, delivering high‑efficiency heating and reduced natural gas costs.

Q: Why is the CHPTA2426B3 coil important?
A: The evaporator coil with a factory‑installed TXV precisely regulates refrigerant flow, enhancing cooling efficiency, comfort, and system responsiveness.

Q: What refrigerant does the system use?
A: The system uses R32 refrigerant, which provides higher energy efficiency and a lower environmental impact than many older refrigerants.

Q: What installation configuration does it support?
A: This system is designed for horizontal installation, perfect for attics, closets, or other tight mechanical spaces requiring sideways airflow.


Maintenance Tips
  • Replace Air Filters Every 1–3 Months: Maintains airflow, protects both furnace and AC components, and ensures efficiency.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.

  • Clean Outdoor AC Condenser: Rinse coils every 3–6 months to preserve SEER2 efficiency and prevent debris buildup.

  • Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.

  • Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 performance.

  • Maintain Condensate Drains: Keep both furnace and AC drain lines clear to prevent water issues or system shutdowns.

  • Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.

  • Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.

Paolo Rossi is offering Free Shipping on all orders.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Customer's Love

★★★★★

I’ve never experienced such comfort and style together.

Adeel Khan
Lahore, Pakistan.
★★★★★

The quality speaks for itself. Highly recommend!

Mehmood Aslam
Islamabad, Pakistan.
★★★★★

I’m genuinely impressed with the detail and finish.

Owais Malik
Karachi, Pakistan.

Recently viewed