Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031
Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031

Goodman - 2 Ton/40,000 BTU Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031

Regular price$4,607.00
/

  • Free worldwide shipping

Goodman - 2 Ton/40,000 BTU  Ultra-Low NOx Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPUM32404031

The Goodman GPUM32404031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 81% AFUE, the GPUM32404031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.

Features
  • 2 ton, 40,000 BTU packaged unit
  • 13.4 SEER2, 81% AFUE
  • Downflow or horizontal discharge installation options
  • Fully charged and ready to install
  • Low sound output
  • Ultra-Low NOx compliant
Specifications
2 Ton 40,000 BTU 13.4 SEER2 Goodman Ultra-Low NOx Gas Packaged Unit - R32
SKU GPUM32404031
Weight (in lbs) 435.000000
AHRI Certificate Number 209319523
Brand/Manufacturer Goodman
Replaces GPG1424040M41
Product Features Ultra-Low NOx
Furnace Efficiency / AFUE 80%
Cooling BTU 23,000 BTU
Heating BTU 40,000 BTU
Blower Motor Multi-Speed
Maximum CFM 800
Decibel Level (dBA) 78 decibels
Configuration Downflow/Horizontal
Refrigerant R32
SEER2 (Efficiency) 13.4
Condenser Stages Single Stage
Compressor Type Scroll
Electrical 208/230v 1 Phase 60 Hz
Max Breaker Size 35 Amps
Min. Breaker Size 21.6 Amps
Tonnage 2 Ton
Low NOx Ultra Low NOx
Fuel Type Natural Gas
Height 34 3/4"
Width 47"
Depth 51"
Manual
What our Experts Think
  • Compact All‑In‑One Comfort: The Goodman GPUM32404031 Packaged Unit combines gas heating and electric cooling in a single packaged system, eliminating the need for a separate furnace or air handler — perfect for tight rooftops, next‑to‑building installs, or homes without indoor HVAC space.

  • Cleaner Combustion (Ultra‑Low NOx): Designed to meet Ultra‑Low NOx emission standards, it’s a great choice for regions with strict air‑quality regulations while reducing environmental impact compared with standard models.

  • Balanced Year‑Round Performance: With 13.4 SEER2 cooling and ≈81% AFUE heating, this unit delivers a solid mix of energy‑efficient air conditioning and dependable gas heat for everyday use.

  • Flexible Installation: The downflow or horizontal discharge design allows installers to fit the unit in varied ductwork layouts and mechanical spaces without extra components.

  • R32 Refrigerant & Quiet Operation: Uses R32 refrigerant for effective heat transfer with lower environmental impact, and the design includes a multi‑speed blower and scroll compressor for quieter, consistent performance.

  • Durable Build & Warranty Support: Built with a heavy‑gauge, insulated cabinet and corrosion‑resistant coils, and backed by Goodman’s long‑term parts and heat exchanger warranty when registered.

  • Value‑Driven Choice: This unit offers practical efficiency, environmental compliance, and simplified installation, making it a smart packaged HVAC solution for homeowners, modular homes, and light commercial applications.


Q&A

Q: What kind of HVAC unit is this?
A: It’s an all‑in‑one packaged gas‑electric comfort unit combining heating and cooling in a single outdoor cabinet, ideal where indoor furnaces or air handlers aren’t practical.

Q: What cooling and heating capacities does it offer?
A: Provides about 2 tons (~23,000 BTU) of cooling at 13.4 SEER2 and 40,000 BTU of gas heat, offering balanced year‑round comfort.

Q: What does 13.4 SEER2 mean?
A: SEER2 14.3 measures seasonal cooling efficiency under updated test standards — higher SEER2 helps reduce electric cooling costs versus low‑efficiency units.

Q: What does Ultra‑Low NOx mean?
A: “Ultra‑Low NOx” refers to reduced nitrogen oxide emissions to meet stricter air quality standards in many regions.

Q: What refrigerant and electrical specs does it use?
A: Uses R32 refrigerant (more efficient and lower‑impact than older types) and runs on 208/230 V single‑phase power standard for packaged HVAC units.

Q: What type of compressor and blower does it have?
A: Features a single‑stage scroll compressor for dependable cooling and a multi‑speed ECM blower for smooth airflow and quieter operation.

Q: What installation configurations are supported?
A: Designed for downflow or horizontal airflow positions — flexible for roof‑mounts, slab installs, or tight mechanical spaces.

Maintenance Tips
  • Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect the blower and coil.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for even heating and cooling.

  • Inspect Gas & Venting System: Check gas connections, burners, and venting for blockages or leaks to ensure safe operation.

  • Clean Around the Unit: Remove dust, debris, and vegetation around the packaged unit for proper airflow.

  • Check Electrical Connections: Inspect 230V wiring, disconnects, and capacitors for secure and corrosion-free operation.

  • Monitor System Performance: Listen for unusual noises; check heating and cooling output for efficiency.

  • Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, refrigerant charge, fan motor, and safety controls yearly.

Paolo Rossi is offering Free Shipping on all orders.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Customer's Love

★★★★★

I’ve never experienced such comfort and style together.

Adeel Khan
Lahore, Pakistan.
★★★★★

The quality speaks for itself. Highly recommend!

Mehmood Aslam
Islamabad, Pakistan.
★★★★★

I’m genuinely impressed with the detail and finish.

Owais Malik
Karachi, Pakistan.

Recently viewed