Goodman - 2 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - GLXS4BA2410 / CHPTA2426B3 / GD9T960403BN
- Free worldwide shipping
Goodman - 2 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - GLXS4BA2410 / CHPTA2426B3 / GD9T960403BN
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a small house in ideal climates
- 2 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a smaller house (depending on climate)
- 40,000 BTU 96% AFUE natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the downflow or horizontal orientation
- Can be converted to an LP furnace with an optional conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| SKU | GLXS4BA2410 |
|---|---|
| Weight | 132.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN402410 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 24,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27" |
| Width | 26" |
| Depth | 26" |
Owner's Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- Warranty Information
-
CHPTA Installation Manual
- CHPTA Specifications Sheet
- Evaporator Coil Warranty
- GD9T96 Specifications Sheet
What our Experts Think
-
Balanced comfort for small–medium homes: This system combines a **2 ton (24,000 BTU) air conditioner at ~14.3 SEER2 with a 96 % AFUE 40,000 BTU gas furnace, delivering reliable year‑round heating and cooling without oversizing equipment for typical residential spaces.
-
High‑efficiency heating saves fuel: The 96 % AFUE condensing furnace converts almost all fuel into usable heat, cutting heating costs and energy waste compared with lower‑efficiency models.
-
Good SEER2 rating for cooling: A 14.3 SEER2 cooling rating offers above‑average energy performance in its class, helping lower summer electricity bills compared with older or baseline systems.
-
Solid airflow and control: Multi‑speed ECM blower motors and staged gas or multi‑speed operation (depending on furnace variant) provide smoother temperature control, reduced cycling, quieter operation, and better humidity management than single‑stage motors.
-
R‑32 refrigerant for modern performance: Built for R‑32 refrigerant compliance, the condenser enhances cooling efficiency and lowers environmental impact compared to legacy refrigerants.
-
TXV‑equipped evaporator coil: The included CHPTA2426B3 coil with factory‑installed thermal expansion valve helps optimize refrigerant flow and improves overall cooling efficiency and comfort performance.
-
Flexible horizontal installation: Designed for horizontal or multi‑position setups, this system fits attics, crawlspaces, and tight utility areas where vertical configurations aren’t feasible.
-
Durability and peace of mind: Heavy‑gauge steel cabinets, efficient ignition systems, and long 10‑year parts + lifetime heat exchanger warranty (with registration) support long‑term reliability and lower maintenance concerns.
-
Value‑oriented choice: Experts see this configuration as a cost‑effective mid‑efficiency HVAC solution that balances heating efficiency, good cooling performance, modern refrigerant tech, and dependable comfort for everyday residential use.
Q&A
Q: What type of HVAC system is this?
A: This is a complete high-efficiency Goodman HVAC system, featuring a 2‑ton air conditioner (GLXS4BA2410), cased evaporator coil (CHPTA2426B3), and 40,000 BTU 96% AFUE gas furnace (GD9T960403BN) for reliable heating and cooling year-round.
Q: What size home is this system suitable for?
A: A 2‑ton AC system (24,000 BTU) is ideal for small to medium homes, condos, or zones around 900–1,400 sq. ft., depending on insulation, layout, and climate.
Q: How energy efficient is this system?
A: The system delivers 14.3 SEER2 cooling efficiency and a 96% AFUE gas furnace, converting nearly all fuel into usable heat for highly efficient residential comfort.
Q: What refrigerant does the air conditioner use?
A: The condenser uses R‑32 refrigerant, a modern, eco-friendly refrigerant designed to maximize efficiency and minimize environmental impact.
Q: Does the furnace include advanced technology?
A: Yes. The GD9T960403BN furnace features a variable-speed ECM blower motor, providing quieter operation, improved airflow, and consistent indoor temperatures.
Q: Can this system be installed horizontally?
A: Yes. Both the furnace and coil support horizontal airflow installation, suitable for attics, crawl spaces, or closets with limited vertical space.
Q: What components are included in this system?
A: The package includes:
-
GLXS4BA2410 – 2 Ton 14.3 SEER2 outdoor AC condenser
-
CHPTA2426B3 – 2 Ton cased evaporator coil
-
GD9T960403BN – 40,000 BTU 96% AFUE gas furnace
Maintenance Tips
-
Replace air filters every 1–3 months: Prevents dust buildup, maintains airflow, and protects the blower motor.
-
Keep the outdoor condenser clear: Maintain 2–3 ft clearance around the unit and remove leaves or debris for optimal cooling performance.
-
Inspect and clean evaporator coil and drain pan: The CHPTA aluminum coil should be checked periodically to avoid clogs, water leaks, and reduced efficiency.
-
Check refrigerant line insulation: Ensure suction line insulation is intact to maintain energy efficiency.
-
Keep vents and registers unobstructed: Allows balanced airflow for consistent heating and cooling.
-
Schedule annual professional service: A certified HVAC technician should inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls each year.
-
Maintain a clean furnace area: Clear surrounding space to ensure safe operation and optimal airflow for the 96% AFUE furnace.
Paolo Rossi is offering Free Shipping on all orders.