Goodman - 2.5Ton/80,000 BTU Gas Packaged Unit - 15.2 SEER2 - Two Stage - R32 - 230V - GPGM53008031
The Goodman GPGM53008031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 15.2 SEER2 and 80% AFUE, the GPGM53008031 is a high-efficiency packaged unit with a compact designed for rooftop and next-to-building applications.
Features
- 2.5 ton, 80,000 BTU packaged unit
- 15.2 SEER2, 80% AFUE
- Downflow or horizontal discharge installation options
- Fully charged and ready to install
- Low sound output
- Low NOx compliant
Specifications
| 2.5 Ton 15.2 SEER2 80,000 BTU Goodman Gas Packaged Unit - R32 |
| SKU |
GPGM53008031 |
| Weight (in lbs) |
407.000000 |
| AHRI Certificate Number |
209319559 |
| Brand/Manufacturer |
Goodman |
| Replaces |
GPG1630080M41 |
| Furnace Efficiency / AFUE |
80% |
| Cooling BTU |
28,600 BTU |
| Heating BTU |
80,000 BTU |
| Blower Motor |
Multi-Speed |
| Maximum CFM |
950 |
| Decibel Level (dBA) |
76 decibels |
| Configuration |
Downflow/Horizontal |
| Energy Star |
Yes |
| Refrigerant |
R32 |
| SEER2 (Efficiency) |
15.2 |
| Condenser Stages |
Two Stage |
| Compressor Type |
Scroll |
| Electrical |
208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size |
30 amps |
| Tonnage |
2.5 Ton |
| Fuel Type |
Natural Gas |
| Height |
34 1/2" |
| Width |
47" |
| Depth |
51" |
Manual
What our Experts Think
-
All‑Season Comfort Package – A matched HVAC system pairing a 1.5 ton air conditioner with a 60,000 BTU, 80% AFUE gas furnace that delivers reliable cooling in summer and dependable heat in winter.
-
14.5 SEER2 Cooling Efficiency – Meets modern DOE efficiency standards for cost‑effective summer cooling and lower electricity usage than older systems.
-
80% AFUE Gas Furnace – Converts a high percentage of fuel into heat, offering steady home heating at a strong value point.
-
Horizontal Configuration – Engineered for attic or crawl‑space installations with horizontal ductwork, maximizing installation flexibility.
-
R‑32 Refrigerant Ready – Designed for next‑generation R‑32 refrigerant, aligning with current environmental and regulatory standards.
-
Factory‑Matched Evaporator Coil with TXV – Helps ensure precise refrigerant metering and smooth performance across seasons.
-
Durable Construction & Warranty Support – Quality coil and system components backed by Goodman’s limited warranty when registered, increasing long‑term reliability.
-
Balanced Performance & Value – A well‑rounded package that provides efficient cooling and reliable heating at a competitive price point, ideal for small to medium homes.
Q&A
Q: What components are included in this Goodman HVAC package?
A: A complete matched system with a **1.5 ton R32 air conditioner condenser (≈18,000 BTU cooling), a horizontal evaporator coil (CHPTA1822B3) with factory‑installed TXV, and a 96% AFUE 80,000 BTU gas furnace for efficient year‑round comfort.
Q: What size space is this system designed for?
A: This system is typically ideal for small to medium homes (≈700–1,000 sq ft) depending on insulation, layout, and local climate.
Q: What does 14.5 SEER2 mean?
A: 14.5 SEER2 is the cooling efficiency rating — it reflects efficient seasonal cooling performance that helps reduce electricity use and cost compared with older, lower‑SEER units.
Q: What does 96% AFUE mean?
A: 96% AFUE means 96% of the furnace fuel is converted into usable heat, delivering high‑efficiency heating with lower natural gas costs.
Q: What are the key features of the included evaporator coil (CHPTA1822B3)?
A: The horizontal coil is optimized for R32 refrigerant, has an all‑aluminum design, and a factory‑installed TXV, which improves cooling efficiency and system responsiveness.
Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, a modern, more efficient refrigerant with lower environmental impact.
Q: What installation orientation does it support?
A: It’s designed for horizontal left‑or‑right installation, suitable for attics, closets, or compact mechanical spaces.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months: Maintains airflow, protects furnace and AC components, and ensures efficient operation.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.
-
Clean Outdoor AC Condenser: Rinse coils every 3–6 months to maintain SEER2 performance and prevent debris buildup.
-
Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe and efficient furnace operation.
-
Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.
-
Maintain Condensate Drains: Keep furnace and AC drain lines clear to prevent water issues or system shutdowns.
-
Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.
-
Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.