Goodman - 2.5 Ton/80,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630C3
Regular price
$4,838.20
Sale price$4,766.00
Save 1%
/
Free worldwide shipping
Goodman - 2.5 Ton/80,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630C3
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
Features
Ideal size to cover a medium-sized house
2.5 ton, 13.4 SEER2 AC-only condenser
R32: Complies with Clean Air Act New Refrigerant Requirements
Low sound output
Fully charged for up to 15' of line set
Factory-installed filter drier
3 ton horizontal evaporator coil
Can be used with heat pump and AC-only condensers
R32: Complies with Clean Air Act New Refrigerant Requirements
Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
Factory-installed TXV kit
This furnace is ideal to heat a medium-sized house (in average climate conditions)
80,000 BTU 80% AFUE two stage variable speed natural gas furnace
Requires metal flue venting
Can be used in the upflow or horizontal orientation
Can be converted to propane with an LP conversion kit (sold separately)
Innovative design for electrical efficiency, safety, and lower sound output
Specifications
2.5 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32
Balanced Year‑Round Comfort: The Goodman CHPTA3630C3 HVAC System matches an 80% AFUE gas furnace with a 2.5 ton air conditioner, delivering reliable heating and cooling in one coordinated package.
Dependable Heating Performance: With 80% AFUE, the furnace offers steady, cost‑effective warmth for moderate climates and everyday home use.
Horizontal Installation Flexibility: Designed for horizontal duct applications, making it suitable for attics, crawlspaces, or other low‑clearance areas.
R32 Refrigerant Advantage: Uses R32 refrigerant, offering improved heat transfer and a smaller environmental footprint than older refrigerants.
Matched System Benefits: Engineered as a coordinated furnace + AC system to ensure consistent airflow, balanced capacity, and reliable year‑round performance.
Goodman Value & Reliability: Combines solid heating and cooling efficiency with flexible installation, making it a practical, cost‑effective choice for whole‑home HVAC comfort.
Q&A
Q: What’s included in this HVAC system? A: A complete matched cooling and heating split system with: a 2.5 ton R32 air conditioner condenser, a horizontal evaporator coil (CHPTA3630C3), and an 80,000 BTU 80% AFUE gas furnace — all designed for horizontal installation and compatible refrigerant.
Q: How much cooling capacity does the AC unit provide? A: The air conditioner delivers 2.5 tons of cooling (~30,000 BTU) with up to 14.5 SEER2 efficiency, helping lower seasonal cooling costs compared with lower‑SEER models.
Q: What does 80% AFUE mean for the furnace? A: 80% AFUE means about 80 ¢ of every dollar spent on fuel becomes usable heat for your home, making it a standard‑efficiency furnace that balances performance and operating cost.
Q: What refrigerant does this system use and why it matters? A: This system operates on R32 refrigerant, a modern and more environmentally friendly option designed to improve efficiency and meet current environmental regulations.
Q: What type of furnace motor and airflow features are typical? A: The gas furnace uses a multi‑speed ECM blower, which enhances airflow control and quiet operation compared with basic motors, though exact blower specs vary by furnace model.
Q: What installation configuration is supported? A: Designed for horizontal — and often upflow/horizontal — installation, making it a good choice for attics, closets, or spaces with limited vertical height.
Maintenance Tips
Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect both furnace and AC components.
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for even heating and cooling.
Inspect Furnace Venting: Check intake and exhaust pipes for blockages or damage to maintain safe operation.
Clean Around the Units: Maintain 2–3 ft clearance around furnace and condenser to prevent dust buildup and allow proper airflow.
Check Thermostat & Electricals: Verify thermostat settings, gas supply, and 115V/208–230V circuits for proper operation.
Monitor System Performance: Listen for unusual noises from the blower or condenser; reduced heating or cooling may indicate service is needed.
Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, AC refrigerant charge, and safety controls yearly.
Paolo Rossi is offering Free Shipping on all orders.
Customer's Love
★★★★★
I’ve never experienced such comfort and style together.
Adeel Khan
Lahore, Pakistan.
★★★★★
The quality speaks for itself. Highly recommend!
Mehmood Aslam
Islamabad, Pakistan.
★★★★★
I’m genuinely impressed with the detail and finish.