Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3
Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3

Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3

Regular price $4,864.40 Sale price$4,741.00 Save 3%
/

  • Free worldwide shipping

Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3 

A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.

Features
  • All-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.
  • Internal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.
  • Cabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.
  • Condensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.
  • R32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.
Specifications
2.5 Ton 14.3 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS4BA3010
Weight 170.000000
Manufacturer Goodman
Replaces GSXN403010
Product Features New Refrigerant Compliant
Cooling BTU 30,000
Decibel Level (dBA) 71
Horsepower 1/6 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 25 Amps
Min. Breaker Size 15.0 Amps
Tonnage 2.5 Ton
Connection Sweat
Height 32"
Width 29"
Depth 29"
Manual
What our Experts Think
  • Balanced Heating & Cooling Combo: The Goodman CAPTA3026B3 HVAC System pairs a 96% AFUE gas furnace with a 2.5 ton (40,000 BTU) air conditioner, offering year‑round comfort in one matched system.

  • High‑Efficiency Heating: The 96% AFUE furnace maximizes fuel use for lower heating costs and strong winter performance.

  • Energy‑Smart Cooling: With 14.3 SEER2, the air conditioner delivers efficient cooling that helps reduce summer energy bills.

  • Downflow Configuration: Ideal for installations where return air is above the unit, such as closets or attic spaces, enhancing flexibility in tight mechanical areas.

  • R32 Refrigerant Advantage: Uses R32 refrigerant for improved heat transfer and reduced environmental impact compared with older refrigerants.

  • Matched System Performance: Designed as a coordinated furnace + AC package, helping ensure consistent capacity, optimized airflow, and reliable seasonal performance.

  • Goodman Value & Reliability: Combines durable components, proven engineering, and strong comfort control, making it a smart, cost‑effective solution for whole‑home HVAC needs.


Q&A

Q: What comes in this HVAC system package?
A: This complete Goodman HVAC system includes a 2.5 ton 14.3 SEER2 R32 air conditioner condenser, a 40,000 BTU 96% AFUE gas furnace, and a matched evaporator coil (CAPTA3026B3) for upflow/downflow installation.

Q: What cooling capacity does the AC deliver?
A: The air conditioner delivers 2.5 tons (≈30,000 BTU) of cooling — suitable for medium homes when paired with proper ductwork.

Q: What does the 14.3 SEER2 rating mean?
A: SEER2 14.3 measures seasonal cooling efficiency under updated standards — higher SEER2 means better energy efficiency and lower operating costs compared with lower‑rated units.

Q: What does 96% AFUE indicate for the furnace?
A: 96% AFUE means about 96 ¢ of every $1 spent on fuel becomes heat, making this a high‑efficiency furnace that lowers heating bills compared to standard models.

Q: What type of furnace operation is included?
A: The furnace typically features a two‑stage or variable‑speed blower (model‑dependent) for quieter operation, improved comfort, and smoother temperature control.

Q: Is this system compatible with modern refrigerants?
A: Yes — the system uses R32 refrigerant, which offers improved efficiency and reduced environmental impact compared with older refrigerants.

Q: What installation orientations does it support?
A: The included coil and furnace support upflow and downflow (and horizontal) installations, giving flexibility for basements, closets, attics, or utility rooms


Maintenance Tips
  • Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect the furnace blower and AC coil.

  • Keep Vents Clear: Ensure supply and return vents are unobstructed for even heating and cooling.

  • Inspect Furnace Venting: Check intake and exhaust pipes for blockages or damage to maintain safe combustion.

  • Clean Around the Units: Maintain 2–3 ft clearance around both furnace and condenser to prevent dust buildup and allow proper airflow.

  • Check Thermostat & Electricals: Verify thermostat settings, gas supply, and AC/furnace power connections are functioning properly.

  • Monitor AC & Furnace Performance: Listen for unusual noises from the variable-speed blower or condenser; inspect if performance drops.

  • Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, AC refrigerant charge, and safety controls yearly.

Paolo Rossi is offering Free Shipping on all orders.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Customer's Love

★★★★★

I’ve never experienced such comfort and style together.

Adeel Khan
Lahore, Pakistan.
★★★★★

The quality speaks for itself. Highly recommend!

Mehmood Aslam
Islamabad, Pakistan.
★★★★★

I’m genuinely impressed with the detail and finish.

Owais Malik
Karachi, Pakistan.

Recently viewed