Goodman - 1.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - GLXS4BA1810 / CHPTA2426B3 / GMVC800603BN
- Free worldwide shipping
Goodman - 1.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - GLXS4BA1810 / CHPTA2426B3 / GMVC800603BN
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a small house in ideal climates
- 1.5 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium-size house (in average climate conditions)
- 60,000 BTU 80% AFUE two stage variable speed natural gas furnace
- Requires metal flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| SKU | GLXS4BA1810 |
|---|---|
| Weight | 132.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN401810; GSX140181 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 18,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 1.5 Ton |
| Connection | Sweat |
| Height | 27" |
| Width | 26" |
| Depth | 26" |
Owner's Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
-
Warranty Information
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- Evaporator Coil Warranty
- GMVC80 Installation Manual
- GMVC80 Brochure
What our Experts Think
-
Ideal for smaller homes and tighter spaces: This 1.5-ton (18,000 BTU) cooling system paired with a 60,000 BTU gas furnace is well-suited for homes roughly 700–1,000 sq. ft., offering balanced heating and cooling without oversizing the equipment.
-
Efficient everyday performance: With 15.2 SEER2 cooling efficiency and 80% AFUE heating, the system provides dependable comfort and solid energy efficiency for homeowners seeking a reliable mid-efficiency HVAC solution.
-
Next-generation R-32 refrigerant: The system uses R-32 refrigerant, which improves cooling efficiency and reduces environmental impact compared to older refrigerants, helping make the system more future-ready.
-
Consistent comfort with variable-speed airflow: The GMVC80 furnace’s variable-speed ECM blower gradually adjusts airflow to maintain stable indoor temperatures, quieter operation, and improved humidity control.
-
Flexible installation design: Designed for horizontal or multi-position installation, the system can be installed in attics, crawl spaces, or mechanical closets—making it adaptable to a wide range of home layouts.
-
Durable construction for long-term reliability: Goodman systems feature heavy-gauge steel cabinets, aluminized heat exchangers, and protective coil guards, helping ensure durability and consistent performance over time.
-
Strong value HVAC package: Our experts view this configuration as a cost-effective all-in-one heating and cooling solution, combining modern refrigerant technology, proven Goodman components, and dependable performance for residential installations.
Q&A
Q: What type of HVAC system is included in this package?
A: This is a complete Goodman central heating and cooling system that includes a 1.5-ton air conditioner (GLXS4BA1810), cased evaporator coil (CHPTA2426B3), and a 60,000 BTU gas furnace (GMVC800603BN) for reliable year-round comfort.
Q: What size home is a 1.5-ton HVAC system best for?
A: A 1.5-ton AC system (18,000 BTU cooling capacity) is generally suitable for small homes, apartments, or zones around 600–1,000 sq. ft., depending on insulation, climate, and layout.
Q: How energy-efficient is this Goodman system?
A: The system provides 15.2 SEER2 cooling efficiency and an 80% AFUE gas furnace, meaning about 80% of the fuel used for heating is converted into usable heat, offering dependable efficiency for residential comfort systems.
Q: What refrigerant does the air conditioner use?
A: The condenser uses R-32 refrigerant, a newer refrigerant designed to improve energy efficiency and reduce environmental impact compared to older refrigerants.
Q: Does the furnace include variable-speed technology?
A: Yes. The GMVC800603BN furnace features a variable-speed ECM blower motor and two-stage gas valve, helping maintain consistent temperatures, quieter operation, and improved airflow control.
Q: Can this system be installed horizontally?
A: Yes. The furnace supports multi-position installation including horizontal airflow, making it suitable for attics, crawl spaces, and other tight installation areas.
Q: What are the main components of this HVAC system?
A: This package includes:
-
GLXS4BA1810 – 1.5 ton 15.2 SEER2 outdoor AC condenser
-
CHPTA2426B3 – cased evaporator coil
-
GMVC800603BN – 60,000 BTU 80% AFUE variable-speed gas furnace
Maintenance Tips
-
Replace air filters every 1–3 months: Clean filters improve airflow, efficiency, and indoor air quality while preventing strain on the blower motor.
-
Keep the outdoor condenser clean: Remove leaves, dirt, and debris and maintain 2–3 ft of clearance around the unit to ensure proper airflow and cooling performance.
-
Inspect evaporator coil and drain line: The CHPTA coil uses an aluminum evaporator with a condensate drain pan—check periodically for clogs or moisture buildup to prevent leaks or mold.
-
Check refrigerant line insulation: Ensure the suction line insulation remains intact to maintain system efficiency and prevent energy loss.
-
Clear and open all vents: Keep supply and return vents unobstructed for balanced airflow throughout the home.
-
Schedule annual HVAC service: A professional technician should inspect the compressor, heat exchanger, blower motor, and refrigerant levels at least once per year to maintain system performance.
-
Keep the furnace area clear: Maintain a clean space around the furnace cabinet to allow proper airflow and safe operation.
Paolo Rossi is offering Free Shipping on all orders.